1107 IM Audio Impedance Tester
Product Overview
It is recommended a drawing be first made of speaker system to verify proper installation Take care to ensure that the system
is not connected to the amplifier Ensure the system under test is not live Check batery, of sysmbol appears on the display,
replace with new batteries Short the tips of the leads, adjust the "0 Ohm ADJ", control to set the reading of zero Connect test
leads to speaker or speaker leads. Note : Speakers may be connected together either in series or parallel to achieve desired
final impedance Rotate the function switch to a suitable range then press the push button to test and take the reading.
Key Features
• Large LCD display 68 x 34 mm (1.338" x 2.677")
• True measurement of speaker systems actural impedance at 1kHz
• Three test ranges allow testing of home theater and commercial sound systems
• Measures transformer impedances
• Battery operation
• Low battery indication
• Data hold function.
• 0Ω adjustment
Spec Comparison
|
1106 IM | 1107 IM |
Measuring ranges | 0-20Ω / 0-200Ω / 0-2kΩ | 0-200Ω / 0-2kΩ / 0-20kΩ |
Test frequency |
1kHz |
|
Accuracy |
20Ω : ±2%rdg±2dgt or ±0.1Ω, which is greater 200Ω/2kΩ : ±2%rdg±2dgt | 200Ω/2kΩ : ±2%rdg±2dgt 20kΩ : ±3%rdg±2dgt |
Low battery indication |
Symbol appears on the display |
|
Data hold indication |
' HOLD ' Symbol appears on the display |
|
Dimensions |
175(L) × 85(W) × 75(D)mm |
|
Power source |
1.5V (AA) × 8 |
|
Safety standard |
EN 61010-1 CAT III 200V ; EN 61326-1 |
Ordering Information
Warranty
• 1 YR
Contents
• 1107 IM Audio Impedance Tester
• Test leads
• Carrying case
• Instruction manual
• Batteries